Parameters | Unit | Values |
Center Wavelength (λc) | nm | 1064 or Specify |
Operating Wavelength Range | nm | +/-10 |
Typ. Insertion Loss at 23℃, Port 3 to Port 1 | dB | 1.0 |
Max. Insertion Loss, Port 3 to Port 1 | dB | 1.4 |
Typ. Peak Isolation, Port 1 to Port 3 | dB | 30~35 |
Min. Isolation at 23℃, Port 1 to Port 3 | dB | 25 |
Tap Ratio, Port 3 to Port 2 | % | 0.1+/-0.03 or Specify |
Min. Extinction Ratio (only for Port 3 to Port 1) | dB | 16 (Double Cladding Fiber) / 18 (Single Cladding Fiber) |
Min. Return Loss (only for Port 1 & 3) | dB | 50 |
Max. Optical Power(CW) | W | 1 , 3 or Specify |
Max. Peak Power | KW | 1.0 |
Max. Tensile Load | N | 5 |
Fiber Type | PM 980 Fiber on Port1 & 2 & 3 | |
Operating Temperature | ℃ | 0 ~ +60 |
Storage Temperature | ℃ | -20 ~ +75 |
A | B | C | D | E | F | G | H |
Wavelength | Package Type | Tap Ratio | Handling Power |
Axis Alignment |
Connector Type on Port 1 & 2 & 3 | Fiber Buffer on Port 1, 2 & 3 | Fiber Length |
06 = 1064nm X = other |
C5 = Type C5 |
01 = 0.1% X = other |
01 = 1W 03 = 3W |
F = Fast Axis Blocked |
N=None X=other |
B = 250um Bare Fiber L = 900um Loose Tube X=other |
1=1.0m X:other |